Whirlpool KDRS807X Range User Manual


 
30" Freestanding and Slide-In Dual Fuel Range
®
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
KDRS807S
KDRS807X
KDSS907S
KDSS907X
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
The cooktop sides of the slide-in range fit over the
cutout edge of your countertop.
If you have a square finish (flat) countertop and the
opening width is 30" (76.2 cm), no countertop
preparation is required.
Formed front-edged countertops must have molded
edge shaved flat ³⁄₈" (1.0 cm) from each front corner of
opening.
Tile countertops may need trim cut back ³⁄₈" (1.0 cm)
from each front corner and/or rounded edge flattened.
If countertop opening width is greater than
30" (76.2 cm), adjust the ³⁄₈" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first
side to side; then front to back. If countertop is not level,
range will not be level. Range must be level for
satisfactory baking conditions.
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe
to the range location. A smaller size pipe on longer
runs may result in insufficient gas supply. Pipe-joint
compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
tape. With LP gas,
piping or tubing size can be ¹⁄₂" (1.3 cm) minimum.
Usually, LP gas suppliers determine the size and
materials used in the system. If local codes permit,
a new CSA design-certified, 4 ft - 5 ft (122 -
152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D.,
flexible metal appliance connector may be used for
connecting range to the gas supply line. A ¹⁄₂"
(1.3 cm) male pipe thread is needed for connection
to the female pipe threads of the inlet to the
appliance pressure regulator. The supply line must
be equipped with a manual shutoff valve. This valve
should be located in the same room but external to
the range. It should be in a location that allows ease
of opening and closing.
When a 4-wire or 3-wire, single phase 120/240 volt,
60 Hz, AC only electrical supply is available, a 50-
amp maximum circuit protection is required. When
a 4-wire or 3-wire single phase 120/208 volt 60 Hz,
AC only electrical supply is available, a 40-amp
maximum circuit protection is required, fused on
both sides of the line. A separate circuit is
recommended. A time-delay fuse or circuit breaker
is recommended.
Ref. W10246120C
1/28/11
Freestanding Range Slide-in Range
30"
(76.2 cm)
30"
(76.2 cm)
30⁹⁄₁₆"
(77.6 cm)
5³⁄₄"
(14.6 cm)
36" (91.4 cm)
cooktop trim
height with
leveling legs
screwed all
the way in*
35⁵⁄₈" (90.5 cm)
height to underside
of cooktop edge
with leveling legs
screwed all
the way in*
41³⁄₄"
(106 cm)
overall height
with leveling
legs screwed
all the way in*
Model/serial number
plate (located on the
right-hand side
oven door trim)
27¼"
(69.2 cm) max.
from handle to
standoff at
back of range**
23" (58.4 cm)
countertop
notch to rear
of countertop
Model/serial
number plate
(located on the
right-hand side
oven door trim)
27¼" (69.2 cm) max.
(27¹¹⁄₁₆" [70.3 cm]
on model KDSS907XSP)
from handle to standoff
at back of range**
30"
(76.2 cm)
30 ¾"
(78.1 cm)
³⁄₈"
(1.0 cm)
*Range can be raised approximately
1" (2.5 cm) by adjusting the leveling legs.
**When installed in a 24" (61 cm) base cabinet
with 25" (63.5 cm) countertop; front of oven
door protrudes 1" (2.5 cm) beyond 24"
(61 cm) base cabinet.
*Range can be raised approximately
1" (2.5 cm) by adjusting the leveling legs.
**When installed in a 24" (61.0 cm) base cabinet
with 25" (63.5 cm) countertop; front of oven
door protrudes 1
³⁄₄" (4.4 cm) (2³⁄₁₆" [5.5 cm] on
models KDRS807XSP and KDSS907XSP)
beyond 24" (61.0 cm) base cabinet.
SLIDE-IN COUNTERTOP PREPARATION
INSTALLATION CLEARANCES
18" (45.7 cm)
upper cabinet
to countertop
18" (45.7 cm)
upper cabinet
to countertop
13" (33 cm) upper
cabinet depth
13" (33 cm) max.
upper cabinet depth
30" (76.2 cm) min.
opening width
30" (76.2 cm) min.
opening width
For minimum
clearance to top
of the cooktop,
see NOTE.
For minimum
clearance to top
of the cooktop,
see NOTE.
30" (76.2 cm)
min. opening
width
30" (76.2 cm)
min. opening
width
This shaded area
recommended for
installation of
rigid gas pipe.
This shaded area
recommended
for installation
of outlet or
junction box.
This shaded area
recommended
for installation
of outlet or
junction box.
Available
area for
gas and
electric
installation.
8"
(20.3 cm)
6"
(15.2 cm)
6"
(15.2 cm)
8"
(20.3 cm)
7" (17.8 cm)
7" (17.8 cm)
1¹⁄₂"
(3.8 cm)
1¹⁄₂"
(3.8 cm)
4¹⁄₂"
(11.4 cm)
4¹⁄₂"
(11.4 cm)
4¹⁄₂"
(11.4 cm)
4¹⁄₂"
(11.4 cm)
5" (12.7 cm) min.
clearance from
both sides of the
range to the side
wall or other
combustible
material.
5" (12.7 cm) min.
clearance from
both sides of the
range to the side
wall or other
combustible
material.
Cabinet door
or hinge
should not
extend into
the cutout.
Cabinet door
or hinge
should not
extend into
the cutout.
³⁄₄" (1.9 cm)
radius both corners
22¹⁵⁄₁₆" (58.3 cm)
opening depth
This shaded area
recommended for
installation of
rigid gas pipe.
Available
area for
gas and
electric
installation.
segnaR nI-edilSsegnaR gnidnatseerF
NOTE: 24" (61 cm) minimum when
bottom of wood or metal cabinet is
covered by not less than ¹⁄₄"
(0.64 cm) flame retardant millboard
covered with not less than No. 28
MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance
between the top of the cooking
platform and the bottom of an
uncovered wood or metal cabinet.
If installing a range hood or
microwave hood combination above
the range, follow the range hood or
microwave hood combination
installation instructions for
dimensional clearances above the
cooktop surface.
†®TEFLON is a registered trademark of E.I. Du Pont
Nemours and Company.
GAS SUPPLY REQUIREMENTS
ELECTRICAL REQUIREMENTS