Whirlpool KEDO-245SS Double Oven User Manual


 
ELECTRICAL
It is necessary to provide an appropriate junction box as shown on the previous page. The installation ot
this junction box and the wiring connecting it to the hollse wiring should be done by a qualified electrician.
All wiring must be done in accordance with the Natioral Electrical Code and/or any other applicable local
codes or ordinances.
The power supply to the junction box must be 120/240 volt or 120/208 volt,
60
hertz A.C. single phase, 3
wire. Do not connect the oven to a D.C. power suppllr as serious damage to the components will result.
Refer to TABLE 1 for fuse or circuit breaker size for
the
model being installed. Remember that the oven
must have a separate circuit. Do not operate other electr cal equipment on the same cirucit.
TABLE 1
Model No.
KESO-140/170
KESO-145/176
SCO- 1243/l 273
SCO-243312733
Maximum Wattage
3.8KW@;40V
Fuse or Breaker
Size Required
30 AMPS
KEDO-2401270
SCO-224312273
KEDO-245/276
SCO-244312743
6.0
KW@ 240 V
7.5
KW @ 240 V
40 AMPS
UNPACKING THE UNIT
The oven should be left on the carton base until it is ready to
put into the cabinet. It is also recommended that the patls over
the door(s) be left in place. These precautions will reduce the
possibility of damage to the front of the unit and the bot om of
the front frame.
Prior to installation, test the electrical service to assure that it
agrees with the specifications on the oven data plate.
Remove all cords, tape and wire used to hold various p3rts in
position during shipment. Remove oven racks from the inide of
the oven and put to one side while oven is being insta led in
cabinet. Take broiler pan and grid from packing on top If the
oven and keep with literature packet in a location when: they
will be retained by the owner.
To Remove Oven Rack8
Slide
rack forward until
bar on back of rack
touches first stop.
Lift front of rack until rear portion of rack
slides out between front two stops.
ELECTRICAL CONNECTION
WARNING: ELECTRICAL AND GROUNDING CONhECTlONS MUST COMPLY WITH THE APPLI-
CABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL
CODES.
WARNING: DISCONNECT ELECTRICAL POWER SU’PLY AND PLACE A TAG AT THE DISCON-
NECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
Connect the conduit from the oven to the junction box jnd properly connect to the power supply leads.
Bare to ground, black to L2, red to Ll, white to neutral or according to local code.)
GROUNDING -THE OVEN MUST BE GROUNDED.
Do not work on the oven wiring until the oven has been pc sitively grounded.
The oven frame is grounded through the bare groundiny wi-e. Connect it to ground in accordance with local
codes. Connect the white neutral to the service neutral win at the junction box.
-3-