4-14
Screw
15. Remove the hex-head screw from the water
recirculation pump shield and remove the
shield.
16. Remove the water fi ll tube from the notch
in the water recirculation pump bracket,
and pull the free end of the water line up,
out of the unit.
Water Distributor
Hose
Refer to the photos at the top of the next col-
umn.
17. Pull out on the left and right water distribu-
tor retainers and remove the tabs from the
slots in the evaporator, disconnect it from
the hose, and remove it.
18. Remove the four screws from the evapo-
rator, then carefully lift the evaporator
just high enough to remove the two right
spacers.
Evaporator
19. Remove the Permagum from the liner
channel.
2 Screws & Spacers
2 Screws
Water Recirculation Pump Shield
Retainer
Tab
Remove Permagum
Water Fill Tube