9
4. Run home power supply cable through strain relief, into
terminal box.
5. Use UL listed wire connectors and connect black wires (C)
together.
6. Use UL listed wire connectors and connect white wires (E)
together.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Duct Covers
NOTE: Remove the film from the vertical duct cover supports and
the duct covers.
1. Attach the vertical duct cover supports using 8 - 4 x 8 mm
screws.
2. Slide the upper duct covers into place, and insert 3 tabs on
each side of the duct covers into the mating slots of the
vertical duct cover supports. Slide the duct covers up until
the springs “click” and the tabs are locked in place.
3. Slide the lower duct covers over the upper duct covers.
4. Attach the lower duct covers together using a plastic bracket
at each top and bottom corner of the lower duct covers
(4 places).
A.Home power supply cable
B.UL listed or CSA approved strain relief
C.Black wires
D.UL listed wire connectors
E.White wires
F. Green (or bare) and yellow-green ground wires
A
B
C
D
E
F
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A.Screws
B.Vertical duct cover support
A.Upper duct cover
B.Spring
A.Upper duct cover
B.Lower duct cover
C.Plastic brackets
B
A
A
B
A
A
B
C
C