12
Make Electrical Connection
1. Disconnect power.
2. Use UL listed wire connectors and connect white wires (A)
together.
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Connect green (or bare) ground wire from power supply to
green ground screw in terminal box and securely tighten.
5. Install terminal box cover.
6. Reconnect power.
Complete Installation
1. Install the 75W (max.) Incandescent light bulb. See
“Replacing the Incandescent Light Bulb” in the “Range Hood
Care” section.
2. Replace grease filter if removed. See the “Range Hood Care”
section.
3. Check the operation of the range hood fan and light. See
“Range Hood Use” section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the “Range Hood Use” section.
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) ground wire
E. Home power supply cable or
power cord accessory kit
F. UL listed or CSA approved
½" strain relief
G. Green ground screw
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
G
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.