Replacing Filters
The grease filters should be removed and cleaned at least once a
month. Do not operate the oven without the filters in place. The
charcoal filter cannot be washed and should be replaced every
6 to 12 months. See “Assistance or Service” to reorder filters.
See “General Cleaning” for cleaning instructions.
To Remove:
1. Remove each of the grease filters by pushing the back of the
filter up, grasping the tab, and sliding the filter to the back.
Pull tab down until the filter drops out.
2. Remove each charcoal filter by pushing the filter toward the
center of the oven until it is clear of the narrow outer lip.
Swing the filter down and slide it out.
To Replace:
1. Replace each charcoal filter by positioning it above the wide
lip near the center of the oven. Swing the filter up into
position and slide it toward the narrow lip. The filter will now
be held in position between the lips.
2. Replace each grease filter by inserting the end without the
tab into the frame. Swing other side up and slide into
position.
Replacing Cooktop Light
The cooktop light is a 10W low-voltage halogen capsule bulb.
See “Assistance or Service” section to reorder.
To Replace:
1. Unplug oven or disconnect power.
2. Remove bulb cover mounting screw, and carefully remove
cover.
3. Remove the burned-out bulb.
4. Replace bulb, using a tissue to handle the bulb, or wearing
cotton gloves. Do not touch bulb with bare fingers.
5. Replace bulb cover and mounting screw.
6. Plug in oven or reconnect power.
Replacing Oven Light
The oven light is a candelabra base bulb. It will automatically
come on when the door is opened and when the oven is
operating. See “Assistance or Service” section to reorder.
To Replace:
1. Unplug oven or disconnect power.
2. Pull the vent grille out.
3. Lift up the bulb cover.
4. Replace light. Close bulb cover.
5. Slide the bottom of the vent grille into place. Push the top
until it snaps into place.
6. Plug in oven or reconnect power.
1. Bulb cover
1