SERVICE
Whirlpool Europe ADG 955 NBM 12.07.1999 / Page 3
Customer Service 8542 955 10420 Doc. No: 4812 718 14583
Technical data
Flow rates / Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min) 208 lmp/l
Spray pump ~ 70 l/min
Drain pump 16 l/min
Pump height max. 1.1 m
Inlet valve 4.5 l/min
Valve for Zone washing 30 l/min
Spray arm lower 33 l/min
Sprayarm upper 27 l/min
Ceiling rotor 10 l/min
Electrical data
Base data
Voltage 220/230 V
Frequency 50 Hz
Total power 2.0-2.2 kW
Fuse 10 A
Motor
Spray pump motor
Voltage 230/240 V
Power consumption 160 W
HI 81 Ω
HA 44 Ω
Capacitor 4 µ F
Drain pump motor
Voltage 220/240 V
Power consumption 30 W
Resistance 146 Ω
Heating
1 Element system
Voltage 220/230 V
Power consumption 1.87/2.04 kW
Resistance 24.5 Ω
Heating speed ~ 2.0 ˚C/min
Temperature on surface ~ 115 ˚C
Safety thermostat
self reset 85 ˚C
Potentiometer
Points of measurement: 1 (black) to 2 (middle)
Position 0 0.0 kΩ
Position 1 0.5 kΩ
Position 2 1.0 kΩ
Position 3 1.4 kΩ
Position 4 1.8 kΩ
Position 5 2.3 kΩ
Position 6 2.6 kΩ
Water valves
Inlet valve
Voltage 220/240 V
Frequency 50/60 Hz
Resistance 3.76 kΩ
Regenerating valve
Voltage 220/240 V
Frequency 50/60 Hz
Resistance 3.13 kΩ
Valve for zone washing
Voltage 220-240 V
Frequency 50/60 Hz
Resistance 4 kΩ
Coil of dispenser
Voltage 220/240 V
Frequency 50/60 Hz
Resistance 1.5 kΩ
Reedcontact
flow meter
salt control