Whirlpool UXT4030AYS Ventilation Hood User Manual


 
7
Install Range Hood
1. Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
2. Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.
3. Install the 4 - 4.5 mm x 13 mm mounting screws in pilot
holes. Leave about ¹⁄₄" (6.4 mm) space between screw heads
and cabinet to slide range hood into place.
Non-vent (recirculating) installations - Do not remove any
knockouts.
Power Supply Cable Installation
1. For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards
and local codes and ordinances. There must be enough
wiring from the fused disconnect (or circuit breaker) box to
make the connection in the hood electrical terminal box.
For optional power supply cord kit installations, follow the
instructions in the “Make Electrical Connections” section.
NOTE: Do not reconnect power until the installation is
complete.
2. Remove the screw from the terminal box cover. Remove
terminal box cover and set aside.
3. Remove the power supply knockout from the top or rear of
the vent hood (depending on the incoming location of your
home power supply cable) and install a UL listed or CSA
approved ¹⁄₂" strain relief.
4. Using 2 or more people, lift the hood into final position. Feed
enough electrical wire through the ½" UL listed or CSA
approved strain relief to make connections in the terminal
box. Tighten the strain relief screws.
5. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall so that the screws are in the neck of the slots.
Tighten the mounting screws, making sure the screws are in
the narrow neck of slots.
A. Keyhole slot
A. Drill pilot hole
A
A
¹⁄₄"
(6.4 mm)
A. Terminal box cover
B. Screw
A. Power supply knockout
A
B
A