Curved-edge glass cooktops
Cabinet Dimensions
IMPORTANT: If installing a range hood or microwave hood
combination above the cooktop, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
NOTES: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened
to avoid interfering with the regulator.
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that
will not operate if plugged into an outlet that is not properly
polarized.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop. See
“Wiring Diagrams” section.
A.21
¹⁄₈
" (53.7 cm)
B. 30
⁵⁄₁₆
" (77.0 cm) on 30" (76.2 cm) models,
36
⁵⁄₁₆
" (92.3 cm) on 36" (91.4 cm) models
C. 2
⁷⁄₈
" (7.3 cm)
A. 30
" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models
B.Combustible area above countertop (shown by dashed box
above)
C. 30
" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of unprotected wood or metal cabinet
(24
" [61 cm] minimum clearance if bottom of wood or metal
cabinet is protected by not less than ¹⁄₄
" [0.6 cm] flame
retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015
" [0.04 cm] stainless steel, or
0.024
" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13
" (33 cm) recommended upper cabinet depth
E. 2
¹⁄₈
" (5.4 cm)
F. 1 9
" (48.3 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to
countertop within minimum horizontal clearances to cooktop
H. Grounded outlet - Locate within 24" (61 cm) of right rear
corner of cutout
I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models
J.8
³⁄₈
" (21.3 cm) minimum distance to nearest left and right side
combustible surface
K. 2
⁷⁄₈
" (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: Anywhere within
6" (15.2 cm) of rear wall is recommended
M. 24" (61 cm) minimum countertop depth is required
A
B
C
B
D
A
C
E
F
H
I
J
G
K
L
M
J
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING