Make Gas Connection
Typical flexible connection
1. Apply pipe-joint compound made for use with Natural and LP
gas to the smaller thread ends of the flexible connector
adapters (see C and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
4. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop base and in a position
where you can reach the regulator access cap.
IMPORTANT: All connections must be wrench-tightened. Do not
make connections to the gas regulator too tight. Making the
connections too tight may crack the regulator and cause a gas
leak. Do not allow the regulator to turn on the pipe when
tightening fittings.
Use only pipe-joint compound made for use with Natural and LP
gas.
Do not use TEFLON
®
tape. You will need to determine the fittings
required depending on your installation.
No appliance below cooktop
A.Manifold entrance
B.Gas pressure regulator
C.Use pipe-joint compound.
D.Adapter (must have ½"
male pipe thread)
E.Flexible connector
F. Adapter
G.Use pipe-joint compound.
H.Manual gas shutoff valve
I.½" or ¾" gas pipe
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
D
E
C
F
G
H
I
Wall oven installed below cooktop
A.Manifold entrance
B.
³⁄₈
" elbow
C.Use pipe-joint compound.
D.Adapter (must have
³⁄₈
" male
pipe thread)
E.Flexible connector (pass
through wall between
cabinets)
F. Adapter (must have
³⁄₈
" male
pipe thread)
G.Use pipe-joint compound.
H.Appliance pressure regulator
(supplied)
I.½" or ¾" gas pipe
J.Manual gas shutoff valve
K.½" or ¾" gas pipe
A.Access cap
B.Rear of cooktop
C.Gas pressure regulator
D.Up arrow. Regulator must be installed with
arrow pointing up to cooktop bottom.
A
B
C
D
F
I
J
K
H
E
G
A
B
C
D