Whynter SNO T-2M/T-2MA Ice Maker User Manual


 
T-2 Version 08/05
7
Appliance Operation (Continued)
deposited into the Ice Drawer recess rather than the Ice Drawer itself. If the appliance does
beep continuously ensure the Ice Cube Drawer is fully in its recess.
The appliance will continue to produce ice cubes at approximately 12 minute intervals.
Some variation in ice cube size should be expected on initial switch on however variation
should be minimized once the appliance has stabilized. Other variables such as water
temperature and ambient operating temperature can affect ice cube size.
When the Ice Cube Drawer is full the appliance will detect this and beep 10 times. The S,
M and L lights will flash for 5 minutes and, if the Ice Cube Drawer is not emptied, the
appliance will go into sleep mode. Emptying the Ice Cube Drawer and replacing it into its
recess will re-start the ice cube making process.
If the Ice Cube Drawer is not emptied the cubes will melt and the water produced will drain
back into the Water Tank through the Ice Cube Drawer drain valve/hole. When sufficient
cubes have melted the ice cube making process will re-start automatically.
As water is drawn from the Water Tank the level will drop and eventually the WATER
TANK indicator on the Function Display will turn from green to red, indicating that the tank
requires topping up. It is not necessary to top up the tank immediately. The ideal time to
top up the tank is a couple of minutes after water has stopped being pumped into the water
tray. The reason for this is that towards the end of the cube production cycle the water tray
inverts and any unfrozen water in the tray drains back into the Water Tank. If the Water
Tank is removed for the purposes of topping up during this period then water will be
deposited into the base of the appliance and then leak onto the surface on which the
appliance is standing.
Care is needed when topping up an appliance that has operated for more than one cycle.
The water top up level should be to approximately 5 mm (¼ inch) below the MAX line of the
Water Level Indicator situated in the front centre of the is Water Tank. This is to allow the
Water Tank to accommodate the contents of the water tray when it inverts without the
Water Tank overflowing.
The appliance can be stopped at any time by pressing the STOP button on the Function
Display. If this is done the START indicator will flash.