NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39080 (04-07)
Model CMJ Series
Gas Infrared Cheesemelter
INSTALLATION REQUIREMENTS:
1. A gas pressure regulator sized for this unit is included.
Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2. Gas line connecting to appliance must be ¾" diameter or
larger. If flexible connectors are used, the inside diameter
must be the same as the ¾" iron pipe.
3. An adequate ventilation system is required for commer
-
cial cooking equipment. Information may be obtained
by writing to the National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org.
When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accordance
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American
Gas Association, Accredited Standards Committee Z223
MODEL NUMBER OF TOTAL APPROX. SHP.
NO. WIDTH DEPTH HEIGHT BURNERS BTU/hr. WT. (lbs./kg)
CMJ24 24" 20½" 19¹⁄₁₆" 1 18,000 106/48
CMJ34 34" 20½" 19
¹⁄₁₆" 1 24,000 159/72
CMJ36 36" 20½" 19¹⁄₁₆" 1 24,000 159/72
CMJ48 48" 20½" 19¹⁄₁₆" 2 36,000 212/95
CMJ60 60" 20½" 19¹⁄₁₆" 2 42,000 265/119
CMJ72 72" 20½" 19¹⁄₁₆" 2 48,000 318/143
@ 400N. Capital St. NW, Washington, DC 20001, or the
Secretary Standards Council, NFPA, 1 Batterymarch Park,
Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or
exhaust system equipped with a damper or with a power
means of exhaust shall comply with 248 CMR.
5. Clearances:
Combustible Non-Combustible
Rear 2" 0"
Sides 20" 0"
Bottom 10" 4"