Wolf ICBCT36E Cooktop User Manual


 
8
E
102 mm
381 mm
381
mm
51 mm*
min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
340 mm
COOKTOP CUT-OUT
WIDTH
340 mm
COOKTOP CUT-OUT
WIDTH
838 mm
RECOMMENDED
CABINET WIDTH
457 mm
NOTE: Application shown allows for installation of two 381 mm modules side-by-side with 838 mm recommended cabinet width. 457 mm
recommended cabinet width for installation of single 381 mm cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 457 mm above countertop.
489 mm
COOKTOP CUT-OUT
DEPTH
64 mm
min
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
330 mm
max
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
FRONT OF COUNTERTOP
64 mm
min
489 mm
COOKTOP
CUT-OUT DEPTH
51**
mm
Overall Dimensions
Countertop Cut-Out
533 mm
OVERALL
DEPTH
381 mm
OVERALL WIDTH
127 mm
96 mm
TERMINAL BOX
MODEL ICBCT15E
Overall Width 381 mm
Overall Height 96 mm
Overall Depth 533 mm
Minimum Cabinet Depth 578 mm
Minimum Height Clearance*
102 mm
Cut-Out Width 340 mm
Cut-Out Depth 489 mm
INSTALLATION SPECIFICATIONS MODEL ICBCT15E
FRAMED MODEL ICBCT15E
The illustrations below provide installation
specifications for Model ICBCT15E.
If Model ICBCT15E is installed above cabinets,
the electrical placement is not critical. A
grounded electrical box should be located
within 1.2 m of the right rear of the cooktop.
For installation above an oven, unless you are
using cabinets deeper than 610 mm, it is
recommended that the electrical supply be
placed in the base cabinet to the right of the
oven.
WOLF
ELECTRIC COOKTOPS
IMPORTANT NOTE:
Do not block the cooling
fan located at the bottom of the cooktop.
*Minimum 146 mm clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 7.
Dimensions may vary to
±
3 mm.