Wolf IRB36 Oven User Manual


 
NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39079 (04-07)
Model IRB36
Gas Infrared Salamander Broiler
INSTALLATION REQUIREMENTS:
1. A gas pressure regulator sized for this unit is included.
Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2. Gas line connecting to appliance must be ¾" diameter or
larger. If flexible connectors are used, the inside diameter
must be the same as the ¾" iron pipe.
3. An adequate ventilation system is required for commer
-
cial cooking equipment. Information may be obtained
by writing to the National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org.
When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accordance
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American
Gas Association, Accredited Standards Committee Z223
Model Grid Rack Total Approx. Shp.
No. Width Depth Height (w x d) BTU/hr. Wt. (lbs./kg)
IRB36 36" 19" 17½" 27½" x 13" 30,000 180/81
@ 400N. Capital St. NW, Washington, DC 20001, or the
Secretary Standards Council, NFPA, 1 Batterymarch Park,
Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or
exhaust system equipped with a damper or with a power
means of exhaust shall comply with 248 CMR.
5. Clearances:
Combustible Non-Combustible
Rear 0" 0"
Sides 2" 0"
Bottom 10" 4"