Wolf WKGX 126623 Convection Oven User Manual


 
FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F32700 (February 2006)Page 11 of 64
3. Reverse the procedure to install the assembly
and check for proper operation.
NOTE: Check to ensure the spark gap distance is
approximately 1/8". If the gap appears to be
excessive or poor sparking is occurring then adjust.
BLOWER AND MOTOR
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1. Take out the racks and rack supports.
2. Remove screws securing the SNORKEL and
remove the snorkel.
3. Remove screws securing baffle panel and
remove the panel.
4. If replacing:
A. Blower Only - Loosen set screws on blower
hub and using a bearing puller, remove blower
from motor shaft.
1) Reverse procedure to install and adjust
blower position as outlined under
BLOWER ADJUSTMENT in SERVICE
PROCEDURES AND ADJUSTMENTS.
B. Motor - perform step 4A and continue
procedure.
5. Remove the screws securing the air baffle to the
rear wall at the lower right hand corner.