Wolf Appliance Company DO30-2F Oven User Manual


 
P
lanning Information
E Series Built-In Double Ovens
MODELS DO30-2F/S AND DO30-2U/S
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Installation
specifications for a double oven installed with a warming drawer with E Series stainless steel drawer front.
STANDARD INSTALLATION OPTION
The Wolf E Series double oven may be installed
in combination with a Wolf warming drawer with
E Series stainless steel drawer front or inte-
grated drawer front. Refer to the illustration
below, and pages 3–6 for installation specifica-
tions for E Series double ovens.
Wolf recommends using 33" (838) cabinets with
this installation. Also, you need a minimum 24"
(610) of usable cabinet depth for the oven.
The base platform for the double oven must be
able to support a weight of 400 lbs (181 kg).
And the warming drawer platform must be able
to support 200 lbs (91 kg).
An anti-tip block or platform must be installed
to prevent the warming drawer from tipping
forward when the drawer is opened. The
warming drawer must be fully enclosed, top and
bottom.
F
or electrical requirements and additional
specifications, refer to the warming drawer
section of our website, wolfappliance.com. Also
refer to the installation instructions provided
with the warming drawer front for detailed
specifications.
28
5
/8" (727)
WARMING DRAWER
OPENING WIDTH
5"
(127)
4"
(102)
E
NOTE:Unless you are using cabinets deeper than 24"(610), it is recommended that the
electrical supply for the oven be placed in an adjacent cabinet within reach of the conduit.
ANTI-TIP BLOCK APPLICATIONPLATFORM APPLICATION
7
/8" (22)
PLATFORM
9
1
/8" (232)
23
7
/8"min (606)
7
/8"
(22)
2
3
/8"
(60)
2"(51) x 2"(51)
ANTI-TIP BLOCK
9
1
/8" (232)
23
7
/8"min (606)
33" (838)
RECOMMENDED CABINET WIDTH
30"min (762)
5"
(127)
E
28
1
/2" (724)
OVEN OPENING WIDTH
4"
(102)
E
E
ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 24" (610)
49
5
/8"
(1260)
24"min (610)
49
5
/8"
(1260)
24"min (610)