Zanussi 110022 Refrigerator User Manual


 
ACTIVE BLAST CHILLER / FREEZERS
100 KG-20 GN 1/1
DCB04 2009-09-23 The Company reserves the right to alter technical specifications without prior notice.
www.zanussiprofessional.com
ZANUSSI
P R O F E S S I O N A L
WATER REMOTE UNIT FOR C/FREEZER CW 100KG 880035
TROLLEY FOR 20X1/1 ROLL-IN RACK 922132 922132
PRINTER FOR HACCP BASIC VERSION 881532 881532
KIT HACCP EKIS 922166 922166
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW 880183 880183
KIT 3 SINGLE SENSOR PROBES FOR BC/BCF 880269 880269
BASE FOR 20X1/1 ROLL-IN RACK 922141 922141
AIR/WATER REMOTE UNIT F.BC+BCF LW 100KG 880059
AIR REMOTE UNIT CHILL+C/FREEZER CW 100KG 880031
80MM PITCH ROLL-IN RACK 14X1/1GN 922205 922205
60-MM PITCH ROLL-IN RACK FOR 20X1/1 922203 922203
3-SENSOR PROBE FOR CHILLER+C/FREEZER 880088 880088
2 SINGLE SENSOR PROBES CHILLER+C/FREEZER 880096 880096
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER 880089 880089
BCF100A
110022
BCF100RA
110024
ACCESSORIES MODELS
OPTIONAL ACCESSORIES
The control unit provides several
operating settings: time/core
temperature according to NF and UK
regulations, time/air
temperature/probe personalised
according to national regulations,
sterilizing cycle: UV lamps built-in
(on request), 3 single sensor or
3-sensor temperature probes (as
accessory), ideal for meats,
automatic defrosting and manual
defrosting. All parameters are
programmable.
The control unit provides two large
displays to read out: time, core
temperature, residual time, alarms,
service information.
Two customizable cycles for each
operating modes, allowing setting
time and air temperature. These two
programs (P1-P2) can be converted
into ice-cream specialist cycles
(shape maintenance and holding).
All information related to the
different operating models are
recorded: date, time, cycle, core
temperature, holding temperature,
HACCP accordance.
An audible alarm starts when the
cycle ends or terminates abnormally.
Chilling times can vary according
to food quantity, density, moisture
contents and type of containers.
Internal and external finishing in
304 AISI stainless steel and
backpanel in galvanized steel.
HCFC, CFC and HFC free
insulation (Cyclopentane), HCFC
and CFC free refrigerant gas
(R404a).
Developed and produced in ISO
9001 and ISO 14001 certified
factory.
Inner cell with rounded corners.
Door equipped with removable
magnetic gasket with hygienic
design.
Evaporator with antirust
protection.
Ventilator swinging panel foreasy
access to the evaporator.
Automatic heated door frame.
Hot gas defrosting system (on
built-in models) or electric defrosting
system (on remote models).
Thermostatic expansion valve to
optimize the cooling unit efficiency.
Adjustable feet 150 mm high.
Stand alone printer as accessory.
PC connection as accessory, gate
RS 485. No water connections
required: Waste water can be
plumbed into drain, but can also be
collected in an optional waste
container.