ACTIVE BLAST CHILLER / FREEZERS
7/15/28 KG.
110721 110722
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER 1 1 1
INCLUDED ACCESSORIES
Power supply - V, phases, Hz 230 V, 1N, 50 230 V, 1N, 50 400 V, 3N, 50
Net weight - kg. 95 105 140
Noise level - dBA 58 63 67
installed-electric 0.831 1.51 1.587
Power - kW
at evaporation temperature - °C -23.3 -25 -30
Refrigerant power
Refrigeration power - W 814 1072 1464
Refrigerant quantity - g. 980 850 1200
Refrigerant type R404a R404a R404a
N° defrost in 24 hrs. 6 3 6
Compressor power - HP 5/8 1
Max load capacity - trays h 65 mm - n° 3 3 6
Trays type GN 1/1; 600x400 GN 1/1; 600x400 GN 1/1; 600x400
Door hinges Right Side Right Side Right Side
N° and type of door 1 1 1
height 850 970 1640
depth/with open doors 700, 1407 760, 1500 760, 1500
width 762 760 760
External dimensions - mm
Cooling unit Built-In Built-In Built-In
Gross capacity (D.I.N. 8952) - l. 72 115 210
UK Guide lines - chilling / freezing 12.5, 7.2 19.5, 15.2 32, 28
NF Regulations - chilling / freezing 7.2, 5.4 10.8 21.6, 21.6
Productivity per cycle - kg.
Power supply Electric Electric Electric
BCF7A
110781
BCF15A
110721
BCF28A
110722
CHARACTERISTICS MODELS
TECHNICAL DATA
RANGE
COMPOSITION
Chilling means bringing the temperature of
cooked food from +90ºC to +3°C in a short
time lap to minimize bacteria proliferation and
avoid loss of food consistency and texture.
The ZANUSSI easyChill Blast
Chillers/Freezers reduce temperature to
+3°C at food core in less than 90 minutes
and down to -18°C in less than four hours.
After the Blast Chilling a holding cycle starts
automatically to respectively maintain food at
+3°C and -18°C. Blast freezed food has a
solid 6 months/1 year shelf life without loss of
flavour, nutritional values and weight. The
opportunity to prepare in a single shot the
food to be used in different times during the
week enables a better work scheduling and
therefore a sensible reduction in labour costs.
FUNCTIONAL AND
CONSTRUCTION
FEATURES
Soft Chilling (Air temperature
–2°C).
Hard Chilling (Air temperature
–20°C).
All the probe-driven cycles feature
ARTE (Algorithm for Remaining
Time Estimation): the machine
displays the actual time needed to
end the cycle and to make planning
the activities easier.
Holding at +3°C (automatically
activated at the end of each cycle).
Turbo cooling: the chiller works
continuously at the desired
temperature. Ideal for continuous
production and for pastry application.
Automatic recognition of the
insertion of the food probe (cycles
piloted either by food probe
temperature or by time)
Single sensor core probe as
standard.