This oven must be installed by qualified
personnel to the relevant British Standards.
Electrical Connection
Installation
The oven is designed to be connected to 240V (50Hz)
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load in
compliance with the current rules.
The switch must not break the yellow and green earth
cable at any point.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a tempera-
ture of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility
should these safety measures not be carried out.
DIMENSIONS Height 580 mm.
OF RECESS Width 560-570 mm.
Depth 550 mm.
DIMENSIONS Height 320 mm.
OF THE Width 420 mm.
OVEN CAVITY Depth 390 mm.
Oven capacity 53.2 litres
Technical Data
The oven must be installed according to the
instructions supplied.
Heating elements rating
Oven element 2.08 kW
Grill element 1.82 kW
Oven Light 15 W
Cooling Fan 25 W
Convection Fan 30 W
Total Rating 2.15 kW
Connection Min. size Cable / flex Fuse
via Cable/flex type
13 A socket 2.5 mm
2
3 core 13 A
outlet butyl min.
13 A insulated
spur box
Cooker 2.5 mm
2
PVC/PVC
15 A min.
Control twin and
20 A max.
Circuit earth
For Uk use only
For Europe use only
Min. size Cable/flex Cable / flex type Fuse
1.5 mm
2
H05 RR-F 13 A