Zanussi ZCG7610 Cooktop User Manual


 
35
Grill
Natural Gas L.P. Gas
Heat Input 2.7kW (9215 Btu/h) 2.45kW (176.5g/h)
Injector marking 121 078
Second oven
Natural Gas L.P. Gas
Heat input 2.4kW (8189 Btu/h) 2.4kW (172.4 g/h)
Injector marking 108 078
Dual control bypass Fixed internal Fixed internal
Main Oven
Heat input 2.4kW (8189 Btu/h)
2.4kW (172.4g/h)
Injector marking 108 078
Thermostat bypass marking 069 078
General
Ignition (H.T. Spark)
Spark gap 3-4mm
Gas category countries of destination
CAT. I
2H
GB
CAT. I
3+
GB
This appliance complies with: European Council Directives Low voltage Directive
73/23/EEC, Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking
Directive 93/68/EEC.