Zanussi ZCG 6600 Cooktop User Manual


 
TECHNICAL DATA
DIMENSIONS
Height Width Depth
Height to hotplate 900mm (nominal) 600mm (nominal) 600mm
(to front of
door panel)
Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level Flush-see important note 'Location of Appliance' page 43.
Minimum space above hotplate 787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Weight of appliance 64.5kg.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas Rear left hand side of cooker at hotplate level.
Rc½ (½" B.S.P. female).
Electric 220V/240V 50 Hz mains 3 core cable is supplied with an integral, moulded plug fitted
with a 3 amp fuse.
IGNITION
Spark generator MG7424/1
GRILL
Natural Gas
Heat Input 3.3kW (11263 Btu/h)
Injector Marking 138
HOTPLATE
Natural Gas
R.H.F. R.H.R. L.H.R. L.H.F
Heat Input 1.0kW 2.0kW 2.0kW 2.8kW
(3412 Btu/h) (6824 Btu/h) ( 6824 Btu/h) (9554 Btu/h)
Injector Marking 079 104 104 130
MAIN OVEN
Natural Gas
Heat Input 2.4kW (8189Btu/h)
Injector Marking 108
Flame Supervision Device Diamond'H' GSD 213
Thermostat Diamond'H' 1100-95/B2
Thermostat By-Pass Marking 69
SECOND OVEN
Natural Gas
Heat Input 2.4kW (8189 Btu/h)
Injector Marking 108
Flame Supervision Device Diamond 'H' GSD 100/31
Dual Control Sourdillon 60112/982
GENERAL
Ignition H. T. Spark
Spark Gap 3-4mm
42