Zanussi ZCM 600 W Range User Manual


 
22
Model Number: ZCM 600W/ZCM610 X
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY
: II 2H3+
APPLIANCE GAS SUPPLY
: Natural Gas 20 mbar
Dimensions
Height 900 mm
Depth 595 mm
Width 597 mm
Oven Capacity 1.8 Cu. ft
Hob
Rear left burner (semi-rapid) 2.0 kW
Front left burner (rapid) 3 kW
Rear right burner (semi-rapid) 2.0 kW
Front right burner (auxiliary) 1.0 kW
Oven
Convection Heating Element 2.080 kW
Grill Element 1.880 kW
Convection Fan 30 W
Oven light 15 W
Total rating 2.125 kW
Supply voltage (50 Hz) 230-240 V
Technical Data
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.65 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.286 0.057 0.190 0.038 0.095 0.028
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 2.8 0.65 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 202 43.5 144 29 72 21,5
NOZZLE REFERENCE 86 40 71 32 50 28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Instructions for the Installer