30
Electrical Connection
The oven is designed to be connected to 230-240V
(50Hz) electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load in
compliance with the current rules.
The switch must not break the yellow and green earth
cable at any point.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a
temperature of more than 60°C above the ambient
temperature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should
these safety measures not be carried out.
Connection Min. size Cable / flex Fuse
via Cable/flex type
• Cooker 6 mm
2
PVC/PVC 30 A
Control twin and
Circuit earth
For Uk use only
For Europe use only
Min. size Cable/flex Cable / flex type Fuse
4 mm
2
H05 RR-F 30 A