Important! Do not remove the spray arms.
If the holes in the spray arms become clogged, remove
remaining parts of soil with a cocktail stick.
External cleaning
Clean the external surfaces of the appliance and control
panel with a damp soft cloth. Only use neutral detergents.
Do not use abrasive products, scouring pads or solvents
(acetone, trichloroethylene etc...).
Frost precautions
Caution! Do not install the appliance where the
temperature is below 0 °C. The manufacturer is not
responsible for damage because of frost.
If not possible, empty the appliance and close the door.
Disconnect the water inlet hose and remove water from
the water inlet hose.
What to do if…
The appliance does not start or stops during operation. If there is a fault, first try to find a solution to the problem
yourself. If you cannot find a solution to the problem
yourself, contact the Service Force Centre.
Fault code and malfunction Possible cause and solution
• continuous flash of the light of the run-
ning programme
• intermittent audible signal
• 1 flash of the end indicator light
The dishwasher does not fill with water
• The water tap is blocked or furred with limescale.
Clean the water tap.
• The water tap is closed.
Open the water tap.
• The filter in the water inlet hose is blocked.
Clean the filter.
• The connection of the water inlet hose is not correct. The hose can
be kinked or squashed.
Make sure that the connection is correct.
• continuous flash of the light of the run-
ning programme
• intermittent audible signal
• 2 flashes of the end indicator light
The dishwasher will not drain
• There is a blockage in the sink spigot.
Clean the sink spigot.
• The connection of the water drain hose is not correct. The hose can
be kinked or squashed.
Make sure that the connection is correct.
The programme does not start • The appliance door is not closed.
Close the door.
• Mains plug is not connected in.
Put in the mains.
• The fuse has blown out in the household fuse box.
Replace the fuse.
After the check, switch on the appliance. The programme
continues from the point of interruption. If the malfunction
shows again, contact your Service Force Centre.
These data are necessary to help you quickly and cor-
rectly:
• Model (Mod.)
• Product number (PNC)
• Serial number (S.N.)
For these data, refer to the rating plate.
Write the necessary data here:
Model description : ..........
Product number : ..........
Serial number : ..........
12