Zanussi ZEA 85 Range User Manual


 
14
Electrical connections
Any electrical work required to install this
hob should be carried out by a qualified
electrician or competent person, in
accordance with the current regulations.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
This hob is designed to be connected to a
230-240V 50Hz AC electrical supply.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the hob rating
plate. The rating plate is located on the bottom of the
hob. A copy is attached on the back cover of this
book.
The hob is supplied without supply cord. A 3 core
flexible supply cord must be fitted, in accordance
with the specification given in the relevant tables.
1) Remove the mains terminal cover plate from
the underside of the hob, to expose the mains
terminal block.
2) Loosen the two cable clamp screws and lift
the top section of the clamp enough to allow
the cable to be passed through.
3) Connect the red (live) wire to the terminal
which is marked with the letter "L".
4) Connect the black (neutral) wire to the
terminal which is marked with the letter "N".
5) After fitting a green or yellow/green sleeve
over the bare copper wire (earth wire), connect
the exposed end to the terminal which is
marked with the earth symbol
or with the
letter "E"coloured green and yellow.
NOTE:
The earth wire should be about 2 cm. longer
than the live and neutral wires.
6) Secure the cable by means of the clamp screws
and refit the terminal block cover.
The hob should be connected to a double pole switch
with a minimum gap of 3 mm. between the switch
contacts and of a type suitable for the required load in
compliance with the current electric regulations. The
switch should be sited within 2m of the hob and be
easily accessible upon completion of the installation.
The switch must not break the yellow and green earth
cable at any point.
Ensure that the hob supply cord does not
come into contact with surfaces with
temperatures higher than 50 deg. C.
L
N
FO 0306
Supply Cable Specifications
Connection Min. size Cable / flex Fuse
via Cable/flex type
Cooker 6 mm
2
PVC/PVC 30 A
Control twin and
Circuit earth
For Uk use only
For Europe use only
Min. size Cable/flex Cable / flex type Fuse
4 mm
2
H05 RR-F 30 A