Zanussi ZFC 21 JC Freezer User Manual


 
5
EN
EN
Is there a power failure?
Is the temperature control set to the Off position?
The alarm remains audible and/or the red light/symbol ( ) is on
Is the lid not closed completely? Check for obstructions.
Is the temperature control set correctly for the surrounding conditions?
Is the freezer too close to a source of heat?
The inside light does not work
Is the power supply cord unplugged?
Is the light bulb loose in the socket, failed or dead?
The motor seems to run too much
Is the lid not closed completely? Check for obstructions.
Is the room termperature hotter than normal?
Has a large amount of fresh food just been added to the freezer?
Is the lid opened often?
Is the temperature control set correctly for the surrounding conditions?
Is the lid seal damaged or deformed?
Is there enough air circulation space around the freezer?
Is the Super Freeze function activated accidentally?
Termperature is too warm
Has a large amount of food just been added to the freezer?
Is the lid opened often?
Is the temperature control set correctly for the surrounding conditions?
Too much ice has formed
Is the lid not closed completely? Check for obstructions.
Is the water drainage plug correctly positioned?
The lid will not close completely
Is there excessive frost or a package preventing the lid from closing?
Are food packages blocking the lid?
Is the lid seal dirty or sticky?
Does the freezer wobble or seem unstable?
The lid is difficult to open
Is the lid seal dirty or sticky?
If you still need help, please contact your local Sercive Force Centre.
Service or repair
In cases of breakdown or faults, your freezer must be serviced by an authorized Electrolux Service Centre.
Important! Under no circumstances should you attempt to repair the appliance yourself.
Technical Data
Climatic classification Ambient temperature limits
SN from +10°C to +32°C
N from +16°C to +32°C
ST from +18°C to +38°C
T from +18°C to +43°C
This appliance complies with the following EC Directives:
73/23/EEC of 19. 02. 1973 Low-Voltage Directive
89/336/EEC of 03. 05. 1989 (including Amendment Directive 92/31/EEC - EMC
Directive)
Model BNI225 BNI280 BNI325 BNI425 BNI525
ZFC21JC ZFC26JC ZFC30JC ZFC40JC ZFC50JC
Volume (gross) Liter 213 263 304 404 500
Volume (net) Liter 210 260 300 400 495
Height cm 87,6 87,6 87,6 87,6 87,6
Width cm 79,5 93,5 105 132,5 160
Depth cm 66,5 66,5 66,5 66,5 66,5
Weight net kg 39 44 49 56 66
Energy consumption
24 Stunden kWh/24 h 0,78 0,878 0,957 1,152 1,338
Freezing capacity kg/24 h 14 16 17 19 20
Hold-over time Hours 26 32 32 31 31
Rated power Watt 84 79 87 82 125
Voltage Volts 230 230 230 230 230