Zanussi ZOB 680 Appliance Trim Kit User Manual


 
electrolux 25
25
Instructions for the Installer
Installation and connection must be
done in compliance with the
regulations in force. Any
interventions must be carried out
when the appliance is switched off.
Only accredited engineers may work
on the appliance.
The manufacturer disclaims any
liability if the safety measures are not
observed.
Connecting to the electrical supply
Before connecting to the electrical supply, please
make sure:
- The fuse and the domestic electrical installation
must be designed for the max. load of the
appliance (see rating plate).
- The domestic electrical installation must be
equipped with a proper earth connection in
accordance with the regulations in force.
- The socket or the multi-pole off switch must be
easy to access after the appliance has been
installed.
This appliance is supplied with a connection
cable incorporating a standard plug, suitable for
the total electric load shown on the rating plate.
The plug is to be inserted into a suitable wall socket.
If you require a direct connection to the electric
network (mains), it will be necessary to fit between
the appliance and the mains an omnipole switch,
with a minimum gap between contacts of 3 mm,
suitable for the required load and in compliance
with rules in force. The green & yellow ground
wire must not be interrupted by the switch and it
should be 2-3 cm. longer than the other cables.
The mains cable and plug as supplied are to
be connected to a shockproof socket (230 V~, 50
Hz). The shockproof socket must be installed in
accordance with the regulations.
The following types of mains cable are suitable,
taking the necessary rated cross section into
account: H07 RN-F, H05 RN-F, H05 RR-F, H05
VV-F, H05 V2V2-F (T90), H05 BB-F.
The connection cable must in any case be laid
out so that at no point does it reach 50°C (over
room temperature).
After the connection has been carried out, the
heating elements must be tested by being operated
for about 3 minutes.
Terminal block
The oven is fitted with an easily accessible terminal
block which is designed to operate with a single-
phase power supply of 230 V.
Letter L - Live terminal
Letter N- Neutral terminal
or E - Earth terminal