Zanussi ZOU 481 Oven User Manual


 
28 electrolux
28
FO 0330
Fig.A
Fig. B
230V 3~
1 2 3 4 5
L1 L2 L3 PE
230V 1~
1 2 3 4 5
L1 N PE
400V 2N~
1 2 3 4 5
L1 L2 N PE
400V 3N~
1 2 3 4 5
L1 L2 L3 N PE
FO 0584
higher than the ambient temperature.
Suitable power supply cables are the following
types, considering the respective necessary
section of cable: H07 RN-F, H05 RN-F, H05 RR-
F, H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
Connecting the terminal board
The appliance incorporates an easily accessible
6-pole terminal board whose jumpers (bridges)
are already pre-set for operation on 400 V
tri-phase with neutral wire (Fig. A). In case a
different mains voltage is present, the jumpers on
the terminal board must be rearranged as shown
in the diagram (Fig. B). The ground cable must be
connected to terminal . After connecting the
supply cable to the terminal board, secure it with a
junction clamp.
Electrical connection with the hob
This oven can be connected to hobs indicated in
the paragraph "Technical data". The socket for
connecting the hob is located at the top of the oven
cabinet. The hobs come complete with connecting
leads for the hot plates/heat areas and ground
cable; these leads feature plug-in connectors.
Connection of the hob to the oven is carried out by
plugging-in these connectors to the corresponding
oven socket.
The plug-to-socket connection design is such as
to prevent possible wrong plugging-ins.
The Manufacturer disclaims any
liability in case these
accident-preventing rules are not
observed.