buildup of frost when it is in operation, neither on the
internal walls nor on the foods.
The absence of frost is due to the continuous circula-
tion of cold air inside the compartment, driven by an au-
tomatically controlled fan.
Technical data
ZRB632FW ZRB634FW ZRB638FW
Dimension
Height 1750 mm 1850 mm 2010 mm
Width 595 mm 595 mm 595 mm
Depth 648 mm 648 mm 648 mm
Rising Time 16 h 18 h 18 h
The technical information are situated in the rating plate
on the internal left side of the appliance and in the ener-
gy label.
Installation
Caution! Read the "Safety Information" carefully
for your safety and correct operation of the
appliance before installing the appliance.
Positioning
Install this appliance at a location where the ambient tem-
perature corresponds to the climate class indicated on
the rating plate of the appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
Location
The appliance should be installed well away from sour-
ces of heat such as radiators, boilers, direct sunlight
etc. Ensure that air can circulate freely around the back
of the cabinet. To ensure best performance, if the appli-
ance is positioned below an overhanging wall unit, the
minimum distance between the top of the cabinet and
the wall unit must be at least 100 mm . Ideally, howev-
er, the appliance should not be positioned below over-
hanging wall units. Accurate levelling is ensured by one
or more adjustable feet at the base of the cabinet.
Warning! It must be possible to disconnect the
appliance from the mains power supply; the plug
must therefore be easily accessible after installation.
A
B
min.100 mm
20 mm
Electrical Connection
Caution! Any electrical work required to install
this appliance should be carried out by a qualified
electrician or competent person.
Warning! This appliance must be earthed.
The manufacturer declines any liability should
these safety measures not be observed.
6