Zenith 30271 Water Dispenser User Manual


 
Page 12 of 20 Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005
Auxiliary Fan Attachment (excluding HT boiling only models)
Auxiliary fan
connection
Cold water
connection
Electrical
connections
The HydroTap is equipped with an auxiliary connection point for an exhaust fan
on the rear panel close to the cold water inlet / flex and plug area. The fan kit
is available as a spare part. The fan operates in parallel with the Condensor
fan helping to remove heat from the cupboard space. This fan should be
purchased and fitted to the HydroTap if the airfow characteristics of the
cupboard space are inadequate for the effective removal of hot air thereby
adversly affecting the operation of the HydroTap.
The fan can be installed so that it extracts air from, or forces air into the
cupboard space, whichever is the most effective for your installation.
Application of the fan is of paramount importance in situations where the
cupboard space reaches temperatures greater than 35ºC.
Boiling Water Safety Isolation (excluding HT boiling only models)
The HydroTap if equipped with a safety mode that allows protection against
accidental operation by Infirmed or disabled persons.
1. On the LCD scroll through the menu to Hot Isolation.
2. Press adjust to activate.
3. Press the safety button on the tap head (3) three times rapidly. The LEDs
will scroll from left to right (3) three times. This operation confirms the
activation.
4. This isolates the boiling tap only. The LCD shows isolation mode is active.
5. To de-activate, press the safety button (3) three times rapidy.
The LED’s will scroll from right to left (3) three times. This operation
confirms de-activation.
6. The LCD will show Normal Operation.
7. If de-activation mode is required, de-activate by scrolling through the
menu and selecting de-activate when Hot Isolation Mode is
displayed on the screen.