Zenith 37201 Water Dispenser User Manual


 
Page 4 of 20 Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005
These Installation Instructions cover the entire Zenith HydroTap range. Use the
chart on the left to identify the model you are using:
Commercial and Domestic Models:
BC = Boiling and Chilled, Filtered, Timer
BF = Boiling, Filtered
BD = Boiling and Ambient Filtered
B = Boiling only (unfiltered)
D = Disabled Lever controls, (Optional order only)
HT = Domestic Models (boiling only are unfiltered, boiling/chilled are filtered)
Boiling Water Capacity:
100 = 100 cups in one hour 150 = 150 cups in one hour
Chilled Water Capacity: (BC only)
125 = 125 glasses in one hour 175 = 175 glasses in one hour
Filtration: (BC, BD and BF only)
Note: The Cup measurement = 167mls, the Glass measurement = 200mls.
Models covered by these instructions
Before installing ensure that the following have been provided at the
installation site:
Sufficient space in the cupboard to install the undersink unit in accordance
with these Installation Instructions. A table of dimensions is given below.
NOTE: Add 65mm to the Depth to the under-sink unit to allow for Water and Electrical connections
A water supply connection with isolating valve inside the cupboard within
reach of the 750 mm flexible connection and positioned so that the
connection point and the stop cock will not be obstructed when the
undersink unit is installed.
Power supply 220-240 Volt AC, for connection to the heater via a 10 amp
G.P.O.
Installation Requirements
BC
Model
100
Cups of
Boiling Water
per Hour
125
Glasses of
Chilled Water
per Hour
Frost Protection
If this appliance is located where the ambient air temperature could fall below 5ºC
when the heater is not in use, do not turn off the appliance electrically. This
safeguard does not offer the same protection to the connecting pipework and
fittings.
Installation Environment Considerations
This unit is intended for indoor use only and should never be installed outdoors
or exposed to the elements of nature. This unit must not be positioned in an
area that may be cleaned by a water jet. This unit must not be cleaned by a
water jet.
# Section Heading# Section Heading
Read These Warnings First continued
Height
mm (inch)
Depth
mm (inch)
Weight empty
kg’s lbs
Weight full
kg’s lbs
337 (13.2) 430 (16.9) 440 (17.3) 28 (61.7) 34.5 (76)
337 (13.2) 430 (16.9) 28 (61.7) 35 (77.1)
395 (15.5) 465 (18.3) 500 (19.6) 29.5 (65) 38 (83.7)
409 (16.1) 340 (13.3) 321 (12.6) 10 (22) 14 (30.8)
353 (13.8) 320 (12.5) 9.5 (20.9) 12 (26.4)
353 (13.8) 320 (12.5) 290 (11.4) 9 (19.8) 11.5 (25.3)
353 (13.8) 320 (12.5) 9 (19.8)
Width
mm (inch)
440 (17.3)
290 (11.4)
290 (11.4)
11.5 (25.3)
Model
BC & HT 60/85
BC 100/125
BC 150/175
B 150
B 100
B 60
BD 60