Zephyr AHZ-M90ARX Ventilation Hood User Manual


 
Installation - Internal Blower
4. Rotate the blower plate
(Note! If air is discharged
from the top, do not rotate
the plate).Place the 6" metal-
lic  ange on the blower's air
outlet (the  ange may alre-
ady be pre-installed). Install
internal blower into blower
plate and secure using (4)
screws included with the blo-
wer. See Fig.4
5. Fasten the two brackets to the
sides of the blower by  xing
them onto the blower plate
with the (4 type B) screws,
and to the sides of the blower
with other (4 type C) screws.
Fig 5
6. Secure capacitor box con-
nected to the provided
cable to the blower plate
using (2 type B) screws in-
cluded with the blower. See.
Fig.6
7. Secure Green/Yellow ground
wire connected to the cable
to the provided capacitor to
blower plate. (type A). Fig.7
- 11 -