Zephyr AK7536ASX Ventilation Hood User Manual


 
13
Installation – CBI-600B Horizontal Ducting Conversion
6. Attach 6” round to rectangular transition adapter
to hood with (4) M4x8 screws.
7. Attach blower brackets to blower with
(4) 10x3/16” screws. (2) screws for each
bracket.
8. Place blower into round end of 6” round
transition adapter. Attach brackets on blower to
blower plate with (4) 3.5x8 screws. (2) screws
for each bracket.
9. Attach rectangular starting collar to hood using
the (6) screws removed from the rectangular
cap in step 4.