Zephyr AK7848ASX Ventilation Hood User Manual


 
14
www.zephyronline.com
SURFACE MAINTENANCE:
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent,
or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine
bleach or orange cleaners.
For heavier soil use liquid degreaser.
After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless
luster and grain. Always scrub lightly using a micro ber or clean cotton cloth and with grain.
Stainless Steel Baf e Filters
The stainless steel bafe lters are intended to trap residue and grease from cooking. Although the lters
should never need replacing, they are required to be cleaned every 30 days or more often depending on
cooking habits.
Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry lters and re-install before
using hood.
Removing Baf e Filters
1. Push lter toward back of range hood using handles.
2. Pivot front of lter downward.
3. Remove lter by pulling away from hood.
Replacing Bafe Filters
Hood Model: Part No. Qty. to Order.
AK7836ASX 50210009 3
AK7842ASX 50210009 3
AK7848ASX 50210009 4
1
2
3
Maintenance – Cleaning and Filter Removal
CAUTION: If this hood is installed in a salt water
area (e.g. coast), rinse all surfaces once a week
with clear water even if the hood is not used.
Wipe and dry completely after rinsing.
!