GENERAL
• Carefully read the following important information regarding installation
safety and maintenance. Keep this information booklet accessible for further
consultations.
POWER SUPPLY CONNECTION
For connection to the power supply refer to
the following:
1. Lift the bottom part of the duct cover and
secure it carefully using adhesive tape.
2. Remove the power supply cover by un-
doing the (2) screws Fig. 11.
3. Break through the hole on the box co-
ver.
4. Secure the power supply conduit to the
cover.
5. Connect the wires of the hood to those of
the power supply as described. Fig.11:
BLACK = L line
WHITE = N neutral
GREEN / YELLOW = G ground
- A double-pole switch properly rated must
be installed to provide the range hood
power supply disconnection.
- Connect the electrical conduit to the Field
Wiring Compartment using listed onduit
ttings.
- Carry out the power supplly connection in
accordance with the national electric code,
ANSI/NFPA 70-1999.
6. Insert the wires into the box, then close the box cover, securing it using the
screws that were previously removed.
7. Remove the adhesive tape from the chimney and place the lower part of the
chimney on the hood.
Installation - Power Supply Connection
- 22 -