Zephyr ASL-E42ASX Ventilation Hood User Manual


 
Installation - Mounting the Range Hood
MOUNTING HEIGHTS
The range hood must be installed at
a minimum height of 24 inches (61
cm) from the cooking surface. If a
connecting duct work composed of
two parts is used, the upper part must
be placed outside the lower part. Do
not connect the range hood duct to
the same duct used to exhaust hot
air or fumes from another appliance.
Before proceeding with the assembly
instructions remove the decorative
mesh  lters so that the range hood
is easier to handle.
MOUNTING TO THE CEILING
The following instructions assume
the installer has access to the attic
or crawl space. Each installation may
be unique to the home.
1. Remove support frame assembly
from the packaging and remove
the (4) screws joining the upper
duct cover to the duct cover cei-
ling bracket.
- Remove the (2) screws to unlock the
top support frame from the bottom support
frame. Fig.9.
Note! If you ordered a recirculating kit please re-
fer to the instructions included inside the kits
prior to installing the hood to the ceiling.
X
B
C
5 - 1/2"
24"
X = C - (5-1/2" + 24" + B)
- 15 -