Zephyr ES1-30AW Ventilation Hood User Manual


 
- 9 -
This range hood must use compact fluorescent lamps (120 V, 13 W, PLC13, 2700 K with
G24q-1 base) (included).
NOTE: The range hood is shipped with both fluorescent lamps packed behind the light diffuser.
1. To access fluorescent lamps, remove the light diffuser by pushing on its both tabs and
pulling it down.
2. To install the fluorescent lamps, slide their 4 prongs into their corresponding holes in their
socket until secured. Reinstall the light diffuser.
To remove fluorescent lamps, remove the light diffuser and pull fluorescent lamps out of
their socket.
NOTE: Some fluorescent lamps may produce a yellowish lighting on first usages. This
temporary effect will disappear by itself.
WARNING
In order to prevent the risk of personal injury, the fluorescent tubes must be
cooled down before removing them.
!
HO0098
1
2
9. FLUORESCENT LAMPS
WARNING
This product contains fluorescent lamps containing mercury. Dispose of
appropriately, according to local laws and requirements.
!
The grease filters, bottom panel,
intake ring (A) and blower wheel (B)
should be cleaned frequently. Use a
warm detergent solution. The grease
filters, intake ring and blower wheel
are dishwasher safe.
HD0220
A
B
10. CLEANING
NOTE: Some minerals, when in contact with dishwasher soap additives, may cause filters
discoloration. This discoloration is not covered by the warranty.