Zephyr ZNA-M90S Ventilation Hood User Manual


 
11
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
from cooking are drawn and ltered by a set of optional charcoal lters. The air is then puri ed and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
work, if possible. The hood is most effective and ef cient as an exhaust hood. Only when the exhaust option
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal lters are required on top of its standard Metal
Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture
residue from cooking and the optional charcoal lters help to purify fumes exhausted from cooking for re-
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal lters and air diverter plate.
Hood Model Part No. Filters in Pkg.
ZNA-M90S ZRC-0060 3
ZNA-E42S ZRC-0060 3
1. Purchase recirculating kit per the part number above.
2. Secure air diverter plate to top support frame. (FIG. F) Open
sides of air diverter plate should face left and right and align
with louver holes on the duct covers. Run 6” ducting from top
of blower housing and secure to air diverter plate. See manual
included with recirculating kit for more detailed instructions.
3. Remove metal mesh lters from hood. Clip charcoal lters onto
each charcoal lter bracket. (FIG. G) The brackets are pre-installed and
located behind the mesh lters.
4. Re-install metal mesh lters.
5. Enable charcoal lter change indicator on control panel. (Refer details
to pg. 13)
6. Charcoal lters must be replaced after every 120 hours of use (or
approximately every 3 to 4 months based on the average of 1 to 2
hrs. of daily cooking time). The microprocessor in the controls when
set, will elapse and count usage time and indicate when charcoal lter
replacement is required every 120 hrs.
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
ZNA-M90S Z0F-C002 3
ZNA-E42S Z0F-C002 3
Charcoal Filter Dimensions:
9in x 6 3/8in
228mm x 162mm
Installation – Ductless Recirculation
D
E
Install charcoal filter (plastic side exposed)
into charcoal filter bracket. Insert tab
cut-out side D of charcoal filter into bracket
first. Lock charcoal filter into place by
pushing down on side E with locking tabs.
front of the hood
back of the hood
FIG. F
FIG. G