Troubleshooting
TROUBLESHOOTING PROCEDURES FOR VERONA
Issue Cause What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s
power is ON.
2. The power line and the cable locking connector
is not connecting properly.
2. Check the power connection with the unit is
connected properly.
3. The switch board and control board wirings are
disconnected.
3. Make sure the wirings between the switch
board and control board are connected
properly.
4. The switch board or control board is defective. 4. Change the switch board or control board.
Light works,
but motor is not
turning.
1. The motor is defective, possibly seized. 1. Change the motor.
2. The thermally protected system detects if the
motor is too hot to operate and shuts the motor
down.
2. The motor will function properly after the
thermally protected system cool down.
3. The switch board or control board is defective. 3. Change defective part.
The unit is
vibrating.
1. The motor is not secure in place. 1. Tighten the motor in place.
2. Damaged blower wheel. 2. Replace the blower.
3. The hood is not secured in place. 3. Check the installation of the hood.
4. The switch board or control board is defective. 4. Change defective part.
The motor is
working, but the
lights are not.
1. Defective LED bulb. 1. Change the LED bulb.
2. The light bulb plug is disconnected 2. Reconnect the light bulb plug
The hood is
not venting out
properly.
1. The hood might be hanging too high from the
cook top.
1. Adjust the distance between the cook top and
the bottom of the hood within 26” and 34”
range.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the
ventilation of the hood.
2. Close all the windows and doors to eliminate
the outside wind fl ow.
3. Blockage in the duct opening or ductwork. 3. Remove all the blocking from the duct work or
duct opening.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting. 5. Change the ducting to at least 8” or higher for
the internal blower.