Overview
2.0 Overview
Use command centers and/or keyswitches to arm the
panel by area. Each panel can have up to four areas.
Each area can have its own account number or areas
can be grouped together with a common account
number. Points of protection are assigned to areas.
Control/
Communicator
On-Board Points
1 to 8
D9131A Module connects
to a parallel printer to print
the event log.
D9133TTL-E allows communication
over a Local or Wide Area network.
D8129 OctoRelay provides alarm
and auxilliary relay output.
(Other functions available.)
D8125 or D8125MUX Interface
used for point expansion.
Each D8128D OctoPOPIT combines
eight POPIT points in one module.
D8132 Modules (two 12 VDC, 7Ah batteries)
provide additional power for command
centers and other powered devices.
Figure 1: System Configuration
2.1 9000G Series Panel Differences
Table 3 provides an overview of the differences between the D9412G, D7412G, and D7212G Panels.
New Features D9412G D7412G D7212G
Access Control YES, 8 Doors YES, 2 Doors NO
Expanded Users
Arm/Disarm Passcodes
Cards/Tokens
249
996
99
396
99
N/A
Passcode-Protected Custom Functions 16 4 4
Number of Printers 3 1 1
Number of Points 246 75 40
Number of Relays 128 64 24
Table 3: Differences between the 9000G Series Panels