PHYSICAL DATA
UNIT SIZE 582A 018040 024040 024060 030040 030060 036060 036090 042060 042090
NOMINAL CAPACITY (ton) 1
1
/
2
222
1
/
2
2
1
/
2
333
1
/
2
3
1
/
2
OPERATING WEIGHT (lb) 249 280 280 280 280 314 314 355 355
COMPRESSOR(S) – QUANTITY Reciprocating-1
REFRIGERANT (R-22)
Quantity (lb) 2.6 3.5 3.5 3.65 3.65 3.75 3.75 5.7 5.7
REFRIGERANT METERING DEVICE Acutrol™ Device
Orifice ID (in.) .034 .034 .034 .034 .034 .032 .032 .034 .034
CONDENSER COIL
Rows—Fins/in. 1—17 1—17 1—17 1—17 1—17 1—17 1—17 1—17 1—17
Face Area (sq ft) 6.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1
CONDENSER FAN
Nominal Cfm 2000 2400 2400 2400 2400 3000 3000 3000 3000
Diameter 22 22 22 22 22 22 22 22 22
Motor Hp (Rpm)
1
/
8
(825)
1
/
8
(825)
1
/
8
(825)
1
/
8
(825)
1
/
8
(825)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
EVAPORATOR COIL
Rows—Fins/in. 2—15 2—15 2—15 2—15 2—15 3—15 3—15 4—15 4—15
Face Area (sq ft) 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1
EVAPORATOR BLOWER
Nominal Airflow (Cfm) 600 800 800 1000 1000 1200 1200 1400 1400
Size (in.) 10x10 10x10 10x10 10x10 10x10 11x10 11x10 11x10 11x10
Motor (Hp)
1
/
4
1
/
4
1
/
4
1
/
4
1
/
4
1
/
2
1
/
2
3
/
4
3
/
4
FURNACE SECTION*
Burner Orifice No. (Qty—Drill Size)
Natural Gas
2—44 2—44 2—38 2—44 2—38 2—38 3—38 2—38 3—38
Burner Orifice No. (Qty—Drill Size)
Propane Gas
2—52 2—52 2—46 2—52 2—46 2—46 3—46 2—46 3—46
RETURN-AIR FILTERS (in.)†
Throwaway Size 20x20x1 20x20x1 20x20x1 20x20x1 20x20x1 20x24x1 20x24x1 20x24x1 20x24x1
UNIT SIZE 582A 048090 048115 048130 060090 060115 060130
NOMINAL CAPACITY (ton) 444555
OPERATING WEIGHT (lb) 415 415 415 450 450 450
COMPRESSOR(S) – QUANTITY Scroll-1 Reciprocating-1
REFRIGERANT (R-22)
Quantity (lb) 6.0 6.0 6.0 8.0 8.0 8.0
REFRIGERANT METERING DEVICE Acutrol Device
Orifice ID (in.) .032 .032 .032 .030 .030 .030
CONDENSER COIL
Rows—Fins/in. 1—17 1—17 1—17 2—17 2—17 2—17
Face Area (sq ft) 12.3 12.3 12.3 12.3 12.3 12.3
CONDENSER FAN
Nominal Cfm 3600 3600 3600 3600 3600 3600
Diameter (in.) 22 22 22 22 22 22
Motor Hp (Rpm)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
1
/
4
(1100)
EVAPORATOR COIL
Rows—Fins/in. 3—15 3—15 3—15 4—15 4—15 4—15
Face Area (sq ft) 4.7 4.7 4.7 4.7 4.7 4.7
EVAPORATOR BLOWER
Nominal Airflow (Cfm) 1600 1600 1600 2000 2000 2000
Size (in.) 11x10 11x10 11x10 11x10 11x10 11x10
Motor (Hp)
3
/
4
3
/
4
3
/
4
1.0 1.0 1.0
FURNACE SECTION*
Burner Orifice No. (Qty—Drill Size)
Natural Gas
3—38 3—33 3—31 3—38 3—33 3—31
Burner Orifice No. (Qty—Drill Size)
Propane Gas
3—46 3—42 3—41 3—46 3—42 3—41
RETURN-AIR FILTERS (in.)†
Throwaway Size 24x30x1 24x30x1 24x30x1 24x30x1 24x30x1 24x30x1
*Based on altitude of 0 to 2000 feet.
†Required filter sizes shown are based on the larger of the ARI (Air Conditioning & Refrigeration
Institute) rated. The filter rack is field convertible to hold a field supplied 2 in. filter.
4