3.9 FIRMWARE UPDATE
The Datalogic Memor™ is equipped with a tool that implements a firmware
update service.
This tool, called Datalogic Updater (DLUpdater), is compatible with all
hardware versions of the following WindowsCE 5.0 models:
Datalogic Skorpio™;
Datalogic Jet™;
Datalogic Kyman™;
Datalogic Memor™.
The DLUpdater, that is automatically invoked at startup, search for a potential
update file (DLUpdate.bin) in the storage card. If it finds it, it proceeds to
update only the components that are damaged or not updated. An update can
be explicitly invoked by running the application DLUpdater.exe, provided
together with the update file. The update must be contained in folder “\Storage
Card”.
CAUTION
It is advisable, even if not binding, to connect the terminal to
an external power source before starting the update
process. This prevents the terminal from turning off while
running and avoids a corruption of flash content.
CAUTION
After the update process, all the data stored in the backup
folder could be irreparably lost, as well as the device
configuration (even that one stored in persistent memory).
Therefore, before starting a firmware update it is advisable
to run a backup copy of the data you want to preserve on
SD Card or on PC (e.g. using ActiveSync).
Retrieving a Firmware Image Update
The following instructions use Internet Explorer to retrieve the most current
firmware image.
1. Launch Internet Explorer on your PC and navigate to
www.mobile.datalogic.com.
2. Navigate the Downloads section of the web site.
3. Select the product, desired language, and software updates. Click Go!
4. Select the file you want to download, then click Save and navigate to the
location where you want to save the firmware files.
5. Click Save again to begin copying the files to your local machine (or local
network location).