NC12S15A_01102008
12
THERMAL CURVES (NC12S0A0H15)
19 (0.75”)
MODULE
A
IR FLOW
9.5 (0.37”)
50.8 (2.0”)
FACING PWB
PWB
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
NC12S0A0H15 (Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout =3.3V (Either Orientation)
0
3
6
9
12
15
25 35 45 55 65 75 85
Output Current(A)
Ambient Temperature (
)
100LFM
Natural
Convection
200LFM
300LFM
Figure 41: Output current vs. ambient temperature and air
velocity@ Vout=3.3V(Either Orientation)
Note: Wind Tunnel Test Setup Figure Dimensions are in
millimeters and (Inches)
Figure 38: Wind tunnel test setup
NC12S0A0H15 (Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout =1.8V (Either Orientation)
0
3
6
9
12
15
25 35 45 55 65 75 85
Ambient Temperature (
)
Output Current(A)
100LFM
Natural
Convection
200LFM
Figure 42: Output current vs. ambient temperature and air
velocity@ Vout=1.8V(Either Orientation)
Figure 39: Temperature measurement location
* The allowed maximum hot spot temperature is defined at 125
NC12S0A0H15 (Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout =5V (Either Orientation)
0
3
6
9
12
15
25 35 45 55 65 75 85
Ambient Temperature (
)
Output Current(A)
100LFM
Natural
Convection
200LFM
300LFM
400LFM
NC12S0A0H15 (Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout =0.9V (Either Orientation)
0
3
6
9
12
15
25 35 45 55 65 75 85
Ambient Temperature (
)
Output Current(A)
100LFM
Natural
Convection
200LFM
Figure 43: Output current vs. ambient temperature and air
velocity@ Vout=0.9V(Either Orientation)
Figure 40: Output current vs. ambient temperature and air
velocity @Vout=5V(Either Orientation)