A SERVICE OF

logo

CONTENTS
page
Technical Data 2
Safety Requirements 3
Provision for Ventilation 3
Location of Appliance 4
Installation 5
Testing 8
TECHNICAL DATA
DIMENSIONS
Height Width Depth
Height to hotplate 900mm (nominal) 600mm (nominal) 600mm
(to front of
door panel)
Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level Flush-see important note 'Location of Appliance' page 4.
Minimum space above hotplate 787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Weight of appliance 64.5kg.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas Rear left hand side of cooker at hotplate level.
Rc½ (½" B.S.P. female).
Electric 230V 50 Hz mains 3 core cable is supplied with an integral,
moulded plug fitted with a 13 amp fuse.
IGNITION
Spark generator APCO 5MG 16913
GRILL
L.P.Gas
Heat Input 3.0kW (215 g/h)
Injector Marking 088
Injector Size 0.88mm
Cone Height Not applicable as flame burns on surface of gauze
HOTPLATE
L.P.Gas
R.H.F. R.H.R. L.H.R. L.H.F
Heat Input 1.0kW 2.0kW 2.0kW 2.7kW
(71.85 g/h) (143.7 g/h) ( 143.7 g/h) (194 g/h)
Injector Marking 051 072 072 083
Injector Size 0.51mm 0.72mm 0.72mm 0.83mm
Cone Length 10mm 15mm 15mm 15mm
2