6-31
2. Press repeatedly until “TP_IF Baud Rate”
appears in the lower line of the menu screen.
3. Press
ENTER
.
The option select screen appears with the current
setting 9600 blinking (blinking indicates “change-
able”).
4. Press or .
The displayed option changes (19200, 2400,
4800 ).
5. When the desired option appears, press
ENTER
to save the change.
The LCD returns to the <<SETUP MODE>>
menu screen (TP_IF Baud Rate).
6. To quit the <<SETUP MODE>>, turn off the
power.
TP_IF Baud Rate
19200
<<SETUP MODE>>
TP_IF Baud Rate
<<SETUP MODE>>
TP_IF Baud Rate
TP_IF Baud Rate
9600
RS232C baud rate
This function sets the baud rate (signaling speed) according to the baud rate of the RS-232C inter-
face. At least, set the speed slower than that of the host interface.
NOTE
You cannot use this function when the setup mode is brought by pressing
in the Ready
status.
Remarks
Unit: baud
LCD display
RS232C Baud Rate
Options
2400, 4800, 9600, 19200 (Default: 4800)
The following is an example of operation when you use this function.