A SERVICE OF

logo

5307880
Installation
Note: See page 7 for the mobile mounting installation. See page 5 for hose and air accessory installation.
Typical Installation For Stationary Mountings
Key
Fluid dispense line
Pump ground wire
Air regulator
Main air supply line
Air filter
Pump lubricator
Pump runaway valve
Follow plate
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
06369B
Stationary Mounting Layout
1. Plan the layout for easy operator access to the
pump air controls, sufficient room to change
drums, and a secure platform.
2. For ease in changing drums, install a pump eleva-
tor.
Open Drum, Cover Mounted Pumps
Models 225014, 225016, 225781, 233108, 244635,
and 244636.
1. Remove the original drum cover.
2. Place the drum cover (3) on the drum, and fasten
it with the screws and washers provided. Carefully
guide the pump riser tube through the mounting
gasket.
Installing the Hose Kit See Fig. 2
For pumps using Hose Kit 222072
1. Install the 3/8” swivel adapter (102) in the pump air
inlet or air regulator line coupler (d) whichever is
applicable. Connect the 3/8” ID air hose (101) to
the swivel. Connect the air hose to the air acces-
sories.
2. Connect the 1/4” swivel adapter (104) to the pump
fluid outlet. Connect the 1/4” ID fluid hose (103) to
the swivel. Connect a suitable dispensing valve or
extra hose to the 6-ft hose.
For pumps using Hose Kit 222076
1. Install the 1/2” swivel adapter (102) in the pump air
inlet or air regulator line coupler (d) whichever is
applicable. Connect the 1/2” ID air hose (101) to
the swivel. Connect the air hose to the air acces-
sories.
2. Connect the 3/8” swivel adapter (104) to the pump
fluid outlet. Connect the 3/8” ID fluid hose (103) to
the swivel. Connect a suitable dispensing valve or
extra hose to the 6-ft hose.