6-3.
E
EL
(~~~ti~~ed)
2.
Using a Phillips head screwdriver, remove the four screws
securing the control panel to the unit, and let panel swing
down. The panel is hinged to hang in this position for
convenience.
3. Disconnect nine-pin connector and remove probe connec-
tion from control panel.
4. To completely remove panel from unit, pull complete con-
trol panel up and out of slots securing the panel.
The thermal sensor, or probe, determines the shortening
temperature. If a malfunction does occur, an E6 will be
displayed on the digital display. Turn unit OFF, then back on,
If E6 persists, the probe must be checked, or replaced by the
following steps:
1. Place the power switch in the OFF position, and remove
power supplied to the unit, or on electric models, to the
cookpot to be worked on.