A SERVICE OF

logo

STEP 3. Attach a 3/4-inch, U.L.-listed,
strain relief to the hole below terminal
block opening. Strain relief should have
a tight fit with laundry center cabinet and
be in a horizontal position. Put the direct
wire cable through the strain relief.
STEP 4. Remove the center terminal
block screw. Remove the neutral ground-
ing wire (green/yellow wire) from external
grounding screw.
GreenP/ellowwire
of harness
Centersilver-colored
terminal blockscrew
External ground
connector
STEP 5. Connect neutral grounding wire
and the neutral wire (white or center) of
direct wire cable under the center screw
of terminal block.
STEP 6. Place the hook-shaped end of
the wire over the terminal block screw.
The open side of the hook should face
to the right. Squeeze hook end of wire
together to form a loop.
STEP 7. Connect the other two wires
to outer terminal block screws. Use the
same method described in STEP 6.
STEP 8. Connect the direct wire cable
(bare) grounding wire to the external-
grounding conductor screw. Securely
tighten all electrical connections.
STEP 9. Tighten the strain relief screws.
STEP 10. Insert tab of terminal block
cover into slot of the laundry center rear
panel. Secure cover with hold-down
screw.
Barecopperwire
Neutral
groundingwire
(green/yellow)
Centersilver-colored
terminalblockscrew
External ground
connector
Neutral wire
(white)
3/4-inch,U.L.-listed,
strain relief
rll
4-Wire Connection with Direct Wire
and Frame-Grounding Conductor
26
f