Check 5/16 '' (8 mm) presetting (distance between
appliance door and lower edge of crosspiece).
u
Raise the fitting aids
Fig. 25 (30)
to the unit door height.
Bottom stop angle ▲of fitting aid = upper edge of the unit
door to be fitted.
u
Unscrew the crosspiece
Fig. 26 (31)
by undoing the
locknuts
Fig. 25 (32)
.
u
Hang the crosspiece
Fig. 26 (31)
on the
inside of the unit door
using the fitting aids
Fig. 26 (30)
.
With a
23-5/8 '' (600 mm)
wide cabinet:
u
To center the
crosspiece
Fig. 26 (31)
: Mark a
short center line on
the unit door and put
the tip of the arrow on
the crosspiece on it.
Fig. 26
w
Distances to the outer edges are the same to the right
and to the left.
With a 24 '' (609.6 mm) wide cabinet:
u
To align the crosspiece
Fig. 26 (31)
: Mark a short center
line on the unit door and put the tip of the arrow on the
crosspiece on it. Then slide the crosspiece
Fig. 26 (31)
3/16 in. (5.5 mm) toward the hinge side.
For chipboard doors:
u
Secure the crosspiece
Fig. 26 (31)
with at least 6 screws
Fig. 26 (34)
.
For frame and panel doors:
u
Secure the crosspiece
Fig. 26 (31)
with 4 screws
Fig. 26 (34)
at the edge.
u
Lift up the fitting aids
Fig. 26 (30)
, turn around and insert
into the adjacent openings.
Fig. 27
u
Attach the unit door on the adjusting bolts
Fig. 27 (33)
and
loosely screw the locknuts
Fig. 27 (32)
onto the adjusting
bolts.
u
Close the door.
u
Check the gap between the door and the surrounding unit
doors.
u
To laterally align the unit door: Move the unit door in the
X direction.
u
To align the unit door in the Y direction (height) and in
lateral inclination: Adjust the adjusting bolts
Fig. 27 (33)
with a screwdriver.
w
The unit door is flush and in alignment with the
surrounding unit fronts.
u
Tighten the locknuts
Fig. 27 (32)
.
Fig. 28
Ensure that both metal edges are flush, symbol //:
u
Drill pilot holes in the door of the unit taking care not to
go all the way through the panel (you could make a
preliminary hole with a bradawl).
u
Screw the appliance door to the unit door with screws
Fig. 28 (34)
through the mounting brackets
Fig. 28 (12)
.
Fig. 29
u
To align the unit door in depth Z: Undo top screws
Fig. 29 (35)
, bottom hex head screws
Fig. 29 (13)
, then
move the door.
u
Do not allow the knobs and sealing lips
to contact the door - important for
functioning!
u
Set an air gap of 3/32 '' (2 mm) between
the door of the unit and the body of the
unit.
Fig. 30
u
Check the fit of the door and re-adjust, if necessary.
u
Tighten all screws.
u
Tighten the locknuts
Fig. 30 (32)
with the ring wrench
Fig. 30 (38)
, while counter-holding the adjusting bolts
Fig. 30 (33)
with a screwdriver.
Installation