A SERVICE OF

logo

28
EXTERNAL CONTROL DEVICE SETUP
ENG
ENGLISH
Command reference list
Communication Parameters
y Baud rate: 9600 bps (UART)
y Data length: 8 bits
y Parity : None
y Stop bit: 1 bit
y Communication code: ASCII code
y Use a crossed (reverse) cable.
y * Note : During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are
not executed and treated as NG.
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
01. Power k a 00 to 01 13. Treble k r 00 to 64
02. Aspect Ratio k c (See p.30) 14. Bass k s 00 to 64
03. Screen Mute k d (See p.30) 15. Balance k t 00 to 64
04. Volume Mute k e 00 to 01
16. Colour
Temperature
x u 00 to 64
05. Volume
Control
k f 00 to 64
17. Energy
Saving
j q 00 to 05
06. Contrast k g 00 to 64
18. Auto Configu-
ration
j u 01
07. Brightness k h 00 to 64
19. Tune
Command
m a
(See p.32)
08. Colour k i 00 to 64
20. Programme
Add/Skip
m b 00 to 01
09. Tint k j 00 to 64 21. Key m c Key Code
10. Sharpness k k 00 to 64
22. Control Back
Light
m g 00 to 64
11. OSD Select k l 00 to 01
23. Input select
(Main Picture
Input)
x b (See p.33)
12. Remote
Control
Lock Mode
k m 00 to 01
(Depending on model)